Upaya pengurangan penguapan air pendingin pada evaporative condenser = Efforts to reduce the evaporation of the cooling water in an evaporative condenser

Hasudungan, Hezkiel Hermawan (2021) Upaya pengurangan penguapan air pendingin pada evaporative condenser = Efforts to reduce the evaporation of the cooling water in an evaporative condenser. Bachelor thesis, Universitas Pelita Harapan.

[thumbnail of Title] Text (Title)
Title.pdf
Restricted to Repository staff only
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (1MB)
[thumbnail of Abstract]
Preview
Text (Abstract)
Abstract.pdf
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (297kB) | Preview
[thumbnail of ToC]
Preview
Text (ToC)
ToC.pdf
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (475kB) | Preview
[thumbnail of Chapter1]
Preview
Text (Chapter1)
Chapter1.pdf
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (338kB) | Preview
[thumbnail of Chapter2] Text (Chapter2)
Chapter2.pdf
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (661kB)
[thumbnail of Chapter3] Text (Chapter3)
Chapter3.pdf
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (443kB)
[thumbnail of Chapter4] Text (Chapter4)
Chapter4.pdf
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (1MB)
[thumbnail of Chapter5] Text (Chapter5)
Chapter5.pdf
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (548kB)
[thumbnail of Chapter6] Text (Chapter6)
Chapter6.pdf
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (239kB)
[thumbnail of Bibliography]
Preview
Text (Bibliography)
Bibliography.pdf
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (302kB) | Preview
[thumbnail of Appendices] Text (Appendices)
Appendices.pdf
Restricted to Repository staff only
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (1MB)

Abstract

Proses pendinginan dibutuhkan karena adanya panas yang dihasilkan dalam pengoperasian mesin. Karena adanya hal tersebut, diperlukan peralatan perpindahan panas meliputi cooler, condenser, heat exchanger, dan lain-lain. Dalam industri, biasanya angin, oli atau air digunakan sebagai media pendingin. Di condenser, proses pendinginan ini terjadi. Saat ini, dalam proses pendinginan pada pabrik es, salah satu cara untuk menurunkan suhu media pendingin adalah menggunakan cooling tower dengan memindahkan panasnya ke lingkungan. Cooling tower memerlukan area yang luas, karena memerlukan condenser dan cooling tower. Evaporative condenser adalah alat gabungan dari condenser dan cooling tower. Pemakaian evaporative condenser saat ini memerlukan konsumsi air yang besar, dengan laju makeup water sebesar 1,5 ton/jam. Dalam penelitian ini, percobaan dilakukan dengan generator Diesel sebagai sumber panas, laju panasnya Q̇M sekitar 12,6 kW dan panas spesifik q yang perlu dipindahkan sekitar 7,6 kJ/kg. Dalam pengaturan eksperimen ini, diusulkan pendinginan air pendingin mesin Diesel sebelum masuk evaporative condenser, dengan menggunakan sebuah heat exchanger pada pipa yang mengalirkan cairan tersebut. Media pendingin untuk heat exchanger adalah air. Eksperimen jenis pertama menggunakan air ledeng. Eksperimen jenis kedua menggunakan air yang dialirkan dari air kolam evaporative condenser. Kedua eksperimen ini menggunakan dua macam aliran air yaitu, parallel flow dan counter flow. Hasil penelitian menunjukkan bahwa secara umum, menggunakan counter flow memberikan hasil yang terbaik. Eksperimen tanpa heat exchanger memberikan laju penguapan sebesar 34 kg/jam. Eksperimen jenis pertama dengan konfigurasi counter flow pada heat exchanger memberikan penurunan pada laju penguapan air sebesar 60% (13,4 kg/jam) dibandingkan dengan pengoperasian normal, sedangkan jenis kedua dengan counter flow pada heat exchanger memberikan penurunan laju penguapan air sebesar 50% (17 kg/jam) dibandingkan dengan pengoperasian normal. Persentase laju penguapan air pendingin di pabrik adalah 1%, dan dari hasil eksperimen didapatkan 1,13%. / Cooling process is needed because of the heat produced by machine operation. Due to that, heat transfer tools such as coolers, condensers, heat exchangers are required. In the industry, cooling mediums that are commonly used are air, oil, and water. The cooling process happens inside a condenser. Currently, in the cooling process of an ice making factory, one of the methods to reduce the temperature of the cooling mediums is to use a cooling tower by transferring the heat to the environment. Cooling towers require a large area, this is because cooling towers must be paired with condensers. An evaporative condenser is a combination of a condenser and a cooling tower. Evaporative condensers today consume large amounts of water, with the rate of makeup water as big as 1.5 tons/hour. In this research, the experiment is done with a Diesel generator as a heat source, with a heat transfer rate Q̇M of approximately 12.6 kW and the specific heat transfer rate q of approximately 7.6 kJ/kg. For the arrangement of the experiment, it is proposed that the hot cooling medium from the Diesel machine is cooled by adding a heat exchanger on the pipe carrying the cooling medium before it enters the evaporative condenser. The cooling medium used inside the heat exchanger is water. The first kind of experiment uses tap water, while the second kind of experiment uses the water from the water tank of the evaporative condenser. Both experiments use parallel flow and counter flow. The research results show that on average, using counter flow provides the best result. The experiment without using the heat exchanger gives the rate of evaporation of water of 34 kg/hour. The first kind of experiment with counter flow arrangement for the heat exchanger gives a reduction in the rate of evaporation of water of 60% (13.4 kg/hour) when compared with normal operation, while the second kind of experiment with counter flow arrangement for the heat exchanger gives a reduction in the rate of evaporation of water of 50% (17 kg/hour) when compared with normal operation. The percentage of the rate of evaporation of the cooling water in the factory is 1%, and from the results of the experiment, the percentage obtained was 1,13%.
Item Type: Thesis (Bachelor)
Creators:
Creators
NIM
Email
ORCID
Hasudungan, Hezkiel Hermawan
NIM01033170026
hezkiel0199@gmail.com
UNSPECIFIED
Contributors:
Contribution
Contributors
NIDN/NIDK
Email
Thesis advisor
Riman, Anthony
NIDN0322074601
UNSPECIFIED
Thesis advisor
Jobiliong, Eric
NIDN0323067204
UNSPECIFIED
Uncontrolled Keywords: evaporative condenser; heat exchanger; perpindahan panas
Subjects: T Technology > T Technology (General) > T55.4-60.8 Industrial engineering. Management engineering
Divisions: University Subject > Current > Faculty/School - UPH Karawaci > Faculty of Science and Technology > Industrial Engineering
Current > Faculty/School - UPH Karawaci > Faculty of Science and Technology > Industrial Engineering
Depositing User: Users 8001 not found.
Date Deposited: 21 Feb 2021 11:15
Last Modified: 03 Mar 2022 22:55
URI: http://repository.uph.edu/id/eprint/21106

Actions (login required)

View Item
View Item