Sartika, Dewi (2015) Perhitungan kecepatan detak jantung janin berdasarkan hasil ekstraksi video echocardiography = The calculation of fetal heart rate based on video echocardiography extraction results. Bachelor thesis, Universitas Pelita Harapan.
![Title [thumbnail of Title]](http://repository.uph.edu/style/images/fileicons/text.png)
Title.pdf
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.
Download (12MB)
![Abstract [thumbnail of Abstract]](http://repository.uph.edu/style/images/fileicons/text.png)
Abstract.pdf
Available under License Creative Commons Attribution Non-commercial Share Alike.
Download (92kB)
![ToC [thumbnail of ToC]](http://repository.uph.edu/style/images/fileicons/text.png)
ToC.pdf
Available under License Creative Commons Attribution Non-commercial Share Alike.
Download (160kB)
![Chapter1 [thumbnail of Chapter1]](http://repository.uph.edu/style/images/fileicons/text.png)
Chapter1.pdf
Available under License Creative Commons Attribution Non-commercial Share Alike.
Download (295kB)
![Chapter2 [thumbnail of Chapter2]](http://repository.uph.edu/style/images/fileicons/text.png)
Chapter2.pdf
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.
Download (904kB)
![Chapter3 [thumbnail of Chapter3]](http://repository.uph.edu/style/images/fileicons/text.png)
Chapter3.pdf
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.
Download (896kB)
![Chapter4 [thumbnail of Chapter4]](http://repository.uph.edu/style/images/fileicons/text.png)
Chapter4.pdf
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.
Download (2MB)
![Chapter5 [thumbnail of Chapter5]](http://repository.uph.edu/style/images/fileicons/text.png)
Chapter5.pdf
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.
Download (291kB)
![Bibliography [thumbnail of Bibliography]](http://repository.uph.edu/style/images/fileicons/text.png)
Bibliography.pdf
Available under License Creative Commons Attribution Non-commercial Share Alike.
Download (161kB)
![Appendices [thumbnail of Appendices]](http://repository.uph.edu/style/images/fileicons/text.png)
Appendices.pdf
Restricted to Repository staff only
Available under License Creative Commons Attribution Non-commercial Share Alike.
Download (260kB)
![Publication Agreement [thumbnail of Publication Agreement]](http://repository.uph.edu/style/images/fileicons/text.png)
Publication Agreement.pdf
Available under License Creative Commons Attribution Non-commercial Share Alike.
Download (375kB)
Abstract
Heart rate is one of the medical medium to diagnose fetal health, so mothers are highly encouraged to check up on their fetal heart rate on regular basis. The medical instrument used to measure fetal heart rate is fetoscope,
doppler, and cardiotography. Doppler is usually utilized on USG and echocardiography; however, incorrect usage of doppler can endanger fetal condition and development. Therefore, based on the aforementioned dilemma, the
solution proposed here is an application which can measure the fetal heart rate through observed changes in the heart region from extracted images of echocardiography video. Four steps are formulated to obtain the fetal heart rate as sequential processes such as pre-enhancement, segmentation, observation of heart region changes, and heart rate calculation. This application will be assessed with four kinds of tests as follows: functionality test, echocardiography video extraction test, performance test, and heart rate calculation accuracy test. In order to distinguish the heart section in an image extracted from echocardiography video, it requires binary imaging process of low pass filter with a certain threshold value. From the extraction, the image is manually cropped to one of cardiovascular chambers, which is ventricle, because of both atrium and ventricle contract separately in turns. Heart rate measurement through visual observations is done to test the application's computational result, with estimated accuracy of 88.82% from six video samples. Although this computation method has not been practiced in medical world, it can be still used as an alternative of heart rate measurement.
Item Type: | Thesis (Bachelor) |
---|---|
Creators: | Creators NIM Email ORCID Sartika, Dewi NIM08220110018 DEWI_SARTIKA2193@YAHOO.COM UNSPECIFIED |
Contributors: | Contribution Contributors NIDN/NIDK Email Thesis advisor Hareva, David Habsara NIDN0316037206 UNSPECIFIED Thesis advisor Lukas, Samuel NIDN0331076001 UNSPECIFIED |
Additional Information: | SK 82-11 SAR p |
Subjects: | Q Science > QA Mathematics > QA75 Electronic computers. Computer science |
Divisions: | University Subject > Current > Faculty/School - UPH Karawaci > School of Information Science and Technology > Informatics Current > Faculty/School - UPH Karawaci > School of Information Science and Technology > Informatics |
Depositing User: | Mr Samuel Noya |
Date Deposited: | 04 Oct 2018 05:43 |
Last Modified: | 03 Aug 2021 08:30 |
URI: | http://repository.uph.edu/id/eprint/608 |